Bought the P1 cable from smartmeterdashboard.nl, and plugged it in:

Mar 26 12:48:18 apollo kernel: [1102994.894619] usb 1-1.4: new full-speed USB device number 6 using xhci_hcd
Mar 26 12:48:18 apollo kernel: [1102994.932321] usb 1-1.4: New USB device found, idVendor=0403, idProduct=6001, bcdDevice= 6.00
Mar 26 12:48:18 apollo kernel: [1102994.932341] usb 1-1.4: New USB device strings: Mfr=1, Product=2, SerialNumber=3
Mar 26 12:48:18 apollo kernel: [1102994.932355] usb 1-1.4: Product: P1 Converter Cable V3
Mar 26 12:48:18 apollo kernel: [1102994.932368] usb 1-1.4: Manufacturer: FTDI
Mar 26 12:48:18 apollo kernel: [1102994.932380] usb 1-1.4: SerialNumber: P15T94ZA
Mar 26 12:48:18 apollo mtp-probe: checking bus 1, device 6: "/sys/devices/platform/scb/fd500000.pcie/pci0000:00/0000:00:00.0/0000:01:00.0/usb1/1-1/1-1.4"
Mar 26 12:48:18 apollo mtp-probe: bus: 1, device: 6 was not an MTP device
Mar 26 12:48:18 apollo kernel: [1102995.079630] usbcore: registered new interface driver usbserial_generic
Mar 26 12:48:18 apollo kernel: [1102995.079690] usbserial: USB Serial support registered for generic
Mar 26 12:48:18 apollo kernel: [1102995.088926] usbcore: registered new interface driver ftdi_sio
Mar 26 12:48:18 apollo kernel: [1102995.088996] usbserial: USB Serial support registered for FTDI USB Serial Device
Mar 26 12:48:18 apollo kernel: [1102995.089154] ftdi_sio 1-1.4:1.0: FTDI USB Serial Device converter detected
Mar 26 12:48:18 apollo kernel: [1102995.089291] usb 1-1.4: Detected FT232RL
Mar 26 12:48:18 apollo kernel: [1102995.094088] usb 1-1.4: FTDI USB Serial Device converter now attached to ttyUSB0
Mar 26 12:48:18 apollo mtp-probe: checking bus 1, device 6: "/sys/devices/platform/scb/fd500000.pcie/pci0000:00/0000:00:00.0/0000:01:00.0/usb1/1-1/1-1.4"
Mar 26 12:48:18 apollo mtp-probe: bus: 1, device: 6 was not an MTP device
Electricity –P1 transfers every second
Value OBIS reference
Equipment identifier 0-0:96.1.1.255
Meter Reading electricity delivered to client (low tariff) in 0,001 kWh 1-0:1.8.1.255
Meter Reading electricity delivered to client (normal tariff) in 0,001 kWh 1-0:1.8.2.255
Meter Reading electricity delivered by client (low tariff) in 0,001 kWh 1-0:2.8.1.255
Meter Reading electricity delivered by client (normal tariff) in 0,001 kWh 1-0:2.8.2.255
Tariff indicator electricity. The tariff indicator can be used to switch tariff
dependent loads e.g boilers. This is responsibility of the P1 user
0-0:96.14.0.255
Actual electricity power delivered (+P) in 1 Watt resolution 1-0:1.7.0.255
Actual electricity power received (-P) in 1 Watt resolution 1-0:2.7.0.255
Number of power failures in any phases 0-0:96.7.21.255
Number of long power failures in any phases 0-0:96.7. 9.255
Power failure event log 1-0:99:97.0.255
Number of voltage sags in phase L1 1-0:32.32.0.255
Number of voltage sags in phase L2 1-0:52.32.0.255
Number of voltage sags in phase L3 1-0:72.32.0.255
Number of voltage swells in phase L1 1-0:32.36.0.255
Number of voltage swells in phase L2 1-0:52.36.0.255
Number of voltage swells in phase L3 1-0:72.36.0.255
Instantaneous voltage L1 1-0:32.7.0.255
Instantaneous voltage L2 1-0:52.7.0.255
Instantaneous voltage L3 1-0:72.7.0.255
Instantaneous current L1 1-0:31.7.0.255
Instantaneous current L2 1-0:51.7.0.255
Instantaneous current L3 1-0:71.7.0.255
Instantaneous active power L1 (+P) 1-0:21.7.0.255
Instantaneous active power L2 (+P) 1-0:41.7.0.255
Instantaneous active power L3 (+P) 1-0:61.7.0.255
Instantaneous active power L1 (-P) 1-0:22.7.0.255
Instantaneous active power L2 (-P) 1-0:42.7.0.255
Instantaneous active power L3 (-P) 1-0:62.7.0.255
Note: Tariff code 1 is used for low tariff and tariff code 2 is used for normal tariff. 